Quick answer. 96-tip and 384-tip formats mirror the 96- and 384-well plate layouts. Choose 96-tip for higher per-well volumes and general transfers, and 384-tip for high-density, low-volume, high-throughput work. The tip must match the pipetting head you’re running.

Automated tips come in racks that mirror microplate density. The format you pick is driven by your plate layout, your transfer volumes and your throughput goals.

96-tip format

A 96-tip rack matches the standard 96-well (8×12) layout and pairs with 96-channel heads. It handles larger per-well volumes and is the workhorse for general liquid handling, reagent additions and plate reformatting. On the Agilent Bravo/VPrep, for instance, the 250 µL tips are a 96-format, 96LT-head consumable.

384-tip format

A 384-tip rack matches the 384-well (16×24) layout and pairs with 384-channel heads. It pipettes four times as many channels per cycle, which is why it dominates high-throughput screening and assay miniaturization — but at smaller working volumes per tip. Lower-volume Agilent Bravo tips (10/30/70 µL) and many Tecan MCA and Hamilton STAR/Vantage tips are 384-format.

Choosing between them

PriorityFormatNotes
Higher per-well volume (≥~100 µL)96-tipLarger tips, fewer channels
High-density / miniaturized assays384-tip4× channels, smaller volumes
Maximum throughput per cycle384-tip384 transfers at once
General reagent transfers, reformatting96-tipFlexible, widely used

The practical constraint is your pipetting head: a 96-channel head needs 96-format tips and a 384-channel head needs 384-format tips. If your instrument has interchangeable heads (common on Tecan MCA and Beckman Biomek), order the tips that match the head for that method.

→ Browse the full, searchable OEM cross-reference catalog, or request free samples to validate on your own deck.

Each instrument guide lists the formats and volumes available for that platform — see the complete cross-reference index.

Frequently asked questions

What is the difference between 96-tip and 384-tip formats?
A 96-tip rack/head matches the 96-well plate layout (8×12); a 384-tip rack/head matches the 384-well layout (16×24). The 384 format pipettes four times as many channels at once but at smaller per-tip volumes.

Which format should I use?
Use 96-tip for higher per-well volumes and general liquid handling, and 384-tip for high-density, low-volume work (e.g. high-throughput screening and assay miniaturization). Your instrument head and plate format usually dictate the choice.

Can one instrument use both formats?
Many platforms offer both 96- and 384-channel heads (for example Tecan MCA and Beckman Biomek). The tip you order must match the head you’re running.

Do 384 tips hold less volume?
Yes — 384-format tips have smaller working volumes than 96-format tips because the wells and channel spacing are smaller. Match the tip volume to your assay’s transfer volumes.

Can I get free samples in either format?
Yes — request free samples in the format and volume you run to validate before ordering a case.

Instrument and product names referenced are trademarks of their respective owners (Agilent, Tecan, Beckman Coulter, Analytik Jena, Revvity/PerkinElmer, Hamilton, QIAGEN, Molecular Devices). Fluotics is an independent manufacturer and is not affiliated with or endorsed by these companies; OEM part numbers are listed solely for cross-reference and compatibility identification.